Reliable EXIN Exam CDCS Simulator offer you accurate Simulations Pdf | EXIN EPI Certified Data Centre Specialist

Tags: Exam CDCS Simulator, Simulations CDCS Pdf, CDCS Valid Practice Materials, Valid CDCS Exam Dumps, CDCS Study Test

CDCS exam dumps provided by ExamBoosts are tested through practice, and are the most correct and the newest practical CDCS test dumps. Our ExamBoosts can provide accurate CDCS certification training questions based on extensive research and the experience of real world to make you pass CDCS Certification Exam in a short time. If you purchase our CDCS exam dumps, we will offer free update service within one year.

ExamBoosts, the best certification company helps you climb the ladder to success. Getting EXIN CDCS certification is setting the pathway to the height of your career. This career-oriented credential opens up vistas of opportunities for you to many medium and large-sized organizations. Such a tremendous opportunity is just a step ahead. Try CDCS Dumps to ensure your success in exam with money back guarantee.

>> Exam CDCS Simulator <<

CDCS Learning Materials Ensure Success in Any CDCS Exam - ExamBoosts

ExamBoosts's practice questions and answers about the EXIN certification CDCS exam is developed by our expert team's wealth of knowledge and experience, and can fully meet the demand of EXIN certification CDCS exam's candidates. From related websites or books, you might also see some of the training materials, but ExamBoosts's information about EXIN Certification CDCS Exam is the most comprehensive, and can give you the best protection. Candidates who participate in the EXIN certification CDCS exam should select exam practice questions and answers of ExamBoosts, because ExamBoosts is the best choice for you.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 2
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of candidates in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.
Topic 3
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q29-Q34):

NEW QUESTION # 29
What indicates the breaking capacity of a fuse or breaker?

  • A. The maximum voltage, in case of an electrical surge, that the fuse or breaker can handle without being destroyed or causing an electric damaging arc.
  • B. Mechanical strength of the casing of a fuse or breaker.
  • C. The current at which the device will trip.
  • D. The current that a fuse or breaker is able to interrupt without being destroyed or causing an electric damaging arc.

Answer: D

Explanation:
The breaking capacity of a fuse or breaker indicates the maximum current it can safely interrupt without being damaged or creating a dangerous arc. This value is crucial for ensuring that the device can handle fault conditions and prevent equipment damage or fire risks due to excessive current flow.
Detailed Explanation:
The breaking capacity, also known as the interrupting rating, ensures that the fuse or breaker can safely handle fault currents up to a specified limit. Exceeding this capacity could result in the device failing to interrupt the current, potentially causing hazardous conditions like electrical arcs.
EPI Data Center Specialist References:
EPI training underscores the importance of matching fuses and breakers with appropriate breaking capacities for the anticipated fault levels in data centers to ensure reliable and safe operation.


NEW QUESTION # 30
You are working on the design of a new facility. The electrical riser of the building with high current power is located close to the area where sensitive IT equipment in the computer room will be located.
What should you recommend to reduce the amount of EMF coming from the electrical riser?

  • A. Install three-phase power cabling based on three individual core wires
  • B. Install single-phase power cabling
  • C. Install bus bar trunking
  • D. Install three-phase power cabling based on a combined cable (e.g. XLPE etc.)

Answer: D

Explanation:
To reduce Electromagnetic Fields (EMF) emanating from the electrical riser near sensitive IT equipment, three-phase power cabling in a combined cable (such as XLPE) is effective. Combined cabling helps reduce EMF by keeping the conductors tightly packed, which minimizes magnetic fields generated by current flow. Cables like XLPE (cross-linked polyethylene) also offer better insulation, which helps mitigate EMF interference with nearby IT equipment.
Detailed Explanation:
Using a combined three-phase cable reduces EMF because the magnetic fields generated by each phase tend to cancel each other out when in close proximity. This arrangement helps reduce the overall magnetic field strength. In addition, XLPE and similar materials provide good insulation, making them a preferred choice for reducing EMF emissions around sensitive equipment.
EPI Data Center Specialist References:
EPI data center best practices recommend mitigating EMF interference through combined cabling arrangements, especially near areas where sensitive IT equipment is located. Reducing EMF is crucial to maintaining equipment reliability and ensuring compliance with safety standards.


NEW QUESTION # 31
The computer room has high levels of H2S gas contamination. What is the best option to resolve this issue?

  • A. Clean the room and racks with a damp/wet cloth.
  • B. Provide more air changes per hour by adding more fresh air to the computer room.
  • C. Vacuum the whole room using a HEPA/S-Class-based filter.
  • D. Install air-scrubbers.

Answer: D

Explanation:
High levels of H2S (hydrogen sulfide) gas contamination in a computer room are best addressed by installing air-scrubbers. Air-scrubbers can effectively filter out contaminants, including corrosive gases like H2S, ensuring clean air circulation and protecting sensitive IT equipment from potential corrosion and damage.
Detailed Explanation:
Air-scrubbers are designed to remove various airborne contaminants and are particularly useful in environments where corrosive gases are present. These systems use filters or chemical reactions to neutralize harmful substances, making them ideal for data centers that need to maintain high air quality for equipment reliability.
EPI Data Center Specialist References:
EPI guidelines suggest air-scrubbing technologies to remove contaminants that pose risks to electronic equipment, maintaining air quality and reducing corrosion risk.


NEW QUESTION # 32
You are changing the design of the fire suppression system for your computer room from a halocarbon fire suppression system into an inert-based fire suppression system. Could you use the same formula to calculate the gas content for the gas?

  • A. Yes, as long as you use the same units of measure, i.e., kg/m³ or lbs/ft³.
  • B. No, there is a significant difference in the formula for the different types of fire suppression gases.
  • C. Yes, as long as you take the difference between the net and gross volume into account.
  • D. Yes, as long as you change the 'S' factor of the formula to reflect the gas type used.

Answer: B

Explanation:
The formula used to calculate the gas content differs significantly between halocarbon and inert-based fire suppression systems. Halocarbon systems function by absorbing heat, while inert systems work by reducing oxygen levels. Due to these differences in fire suppression mechanisms, distinct formulas are applied, factoring in the specific properties of each gas type and the required concentration levels.
Detailed Explanation:
Halocarbon systems like FM200 require a formula that accounts for the concentration needed for cooling, while inert gases like nitrogen or argon need a formula that calculates the volume based on oxygen displacement. As the design concentration and characteristics of these gases differ, it's essential to use the correct formula specific to the gas type.
EPI Data Center Specialist References:
EPI recommends consulting the specific design requirements and formulas provided by each gas manufacturer when switching fire suppression systems to ensure the correct amount of gas is deployed for effective fire suppression.


NEW QUESTION # 33
A data center has its own power supply from the public utility and receives chilled water supply from the building owner.
What needs to be taken into consideration when calculating the PUE?

  • A. You will need to take the value for COP of the chiller plant into consideration
  • B. Nothing, as the chiller plant in the building also uses electrical power
  • C. You will need to take a weight factor of 0.4 for district chilled water into consideration
  • D. PUE calculations are not possible in shared buildings

Answer: C

Explanation:
When calculating Power Usage Effectiveness (PUE) in a data center that uses chilled water from an external source, like from a building owner, a weight factor for district chilled water must be applied. This is because PUE calculations aim to measure the energy efficiency of the data center's own operations, and external utilities like district chilled water aren't directly powered by the data center. A weight factor of 0.4 is typically used to account for the energy consumed to produce and deliver the chilled water, reflecting the indirect impact on the data center's total energy consumption.
Detailed Explanation:
PUE is calculated as the ratio of the total facility energy to the IT equipment energy. If the cooling is provided by an external chilled water source, it's necessary to adjust the calculations to accurately reflect the energy impact. By incorporating the 0.4 weight factor, data centers can calculate a more accurate PUE, aligning with standard methods and industry best practices.
EPI Data Center Specialist References:
EPI training on PUE highlights the importance of adjusting for external energy sources, such as district cooling, in the calculations. This ensures that PUE values remain accurate and comparable across different data centers, even when external utilities are used.


NEW QUESTION # 34
......

We all have the right to pursue happiness. Also, we have the chance to generate a golden bowl for ourselves. Now, our CDCS practice materials can help you achieve your goals. As we all know, the pace of life is quickly in the modern society. So we must squeeze time to learn and become better. With the CDCS Certification, your life will be changed thoroughly for you may find better jobs and gain higher incomes to lead a better life style. And our CDCS exam questions will be your best assistant.

Simulations CDCS Pdf: https://www.examboosts.com/EXIN/CDCS-practice-exam-dumps.html